Background: Indoor air pollutants becoming a great concern for public health. Indoor air pollution can cause more harmful health impacts than that of outdoor air pollution.
Objectives: The study was conducted to investigate some selected indoor air pollutants and respiratory problems among the households of Dhaka city.
Materials and methods: This was a cross sectional study conducted among the households in Dhaka city. A total of 97 households from the selected areas of Dhaka city were included to measure some selected indoor pollutants and 288 individuals from these households were investigated for any respiratory problems. The indoor pollutants were carbon dioxide, carbon monoxide, hydrocarbon, formaldehyde and nitrogen dioxide.
Results: The indoor air the pollutants which were found to be at higher levels in the studied households were carbon dioxide (≥600ppm) in 67.0% households, formaldehyde (≥0.1ppm) in 35.1% households, carbon monoxide (1-5ppm) in 17.5% households and hydrocarbon (≥600ppm) in 9.3% of the households. In most of the households (92.8%) nitrogen dioxide could not be detected. However, hydrocarbon, formaldehyde and carbon monoxide also could not be detected in 7.2%, 30.9% and 73.2% households respectively. The respiratory problems were found to be more in the households with increase concentration of pollutants in the indoor air. In addition, the average concentration of carbon dioxide, formaldehyde and hydrocarbon are found to be significantly (p<0.05) high with the occurrence of respiratory problems. The common respiratory manifestations suffered by the household members were chronic cough (34.4%), cough and chest pain (33.7%); breathlessness and chest tightness (33.3%); running nose and sneezing (30.6%) and wheeze and asthma (26.4%).
Conclusion: The study revealed that the concentrations of some indoor air pollutants were higher in the studied households of Dhaka city. The members of these households were found to suffer more from respiratory diseases, particularly households having significantly higher concentration of carbon dioxide, formaldehyde and hydrocarbon.
Keywords:
Published on: Aug 8, 2016 Pages: 32-36
Full Text PDF
Full Text HTML
DOI: 10.17352/2455-5479.000014
CrossMark
Publons
Harvard Library HOLLIS
Search IT
Semantic Scholar
Get Citation
Base Search
Scilit
OAI-PMH
ResearchGate
Academic Microsoft
GrowKudos
Universite de Paris
UW Libraries
SJSU King Library
SJSU King Library
NUS Library
McGill
DET KGL BIBLiOTEK
JCU Discovery
Universidad De Lima
WorldCat
VU on WorldCat
PTZ: We're glad you're here. Please click "create a new query" if you are a new visitor to our website and need further information from us.
If you are already a member of our network and need to keep track of any developments regarding a question you have already submitted, click "take me to my Query."